SG08-LITE
Install and secure the hard drive cage with screws.為了給電源線保留足夠的容線空間,硬碟架是儘量往右靠的,兩顆2.5"硬碟僅能使用90度的SATA接線,請不要使用180度的SATA接線,否則會蓋不上Dans le but de créer
We recommend connecting all fan or SATA cables to the motherboard now as installation of graphics or expansion card may prevent installation of these
Remove expansion slot screws to remove expansion slot covers.請將鎖固擴充槽檔片的螺絲卸下,再將擴充槽檔片卸下拡張スロットのネジを外して拡張スロットカバーを取り外します。请将锁固扩展槽档片的螺丝卸下,再将扩展槽档片卸下Lösen Sie z
Install graphics or expansion card into the case then connect any required power cables to the card.Reinstall top expansion slot cover back to the cas
Install slim optical drive onto the optical drive bracket and secure with included screws.將風扇架裝回機殼(使用18cm風扇須注意電源插座是被風扇框所包夾住的)並以步驟2卸下的螺絲鎖固将风扇架装回机壳(使用18
Place the top cover back onto the case and secure with screws.將上蓋裝回機殼並以步驟1卸下的螺絲鎖固ケースに上部カバーを戻し、ネジで固定します。将上盖装回机壳并以步骤1卸下的螺丝锁固Platzieren Sie die obere Abd
(1) Front panel connector installation no polarity, so they can be connected in any orientationPower switch and reset switch installation guide:Pleas
Please refer to the motherboard manuals for the motherboard’s “Front Panel Connector ” or “System Panel Connector” pin definition.; the white/black wi
Below are the front I/O connectors pin definition, please also check your motherboard manual to cross reference with motherboard’s front I/O pin heade
The SG08-LITE can accommodate all standard size components and even some that are out of spec, please refer to the following guidelines for component
The ultimate evolution of high performance Mini-ITXFor years, SilverStone Sugo series has been the benchmark and the standard for high-performance Min
Accepte les blocs d'alimentation au standard ATX jusqu'à une longueur de 160mm. Pour accepter une longue carte graphique (de plus de 7,25”),
The PSU above 800w is not recommended because of the adapter cableNetzteile über 800 W sollten aufgrund des Adapterkabels nicht verwendet werdenLes bl
(3) Graphics card/expansion card length limitationSG08-LITE can support 12.2”consumer-level graphics cards (width 4.84”). Due to design, the graphics
(4) Optical drive limitationThe SG08-LITE only supports 12.7mm slim “slot-loading” optical drives.Below is an example of 12.7mm optical drive.Das SG08
Using SilverStone’s NT06-PRO without CPU fan is possible on CPU with TDP rated up to 95W. With a 120mm fan installed on the NT06-P, the use of a CPU w
Cable routing We placed pass-through holes on the back of the case, please use wire ties in places as needed by your hardware configuration.Hinter dem
1. Unscrew screws holding the fan bracket and then pull up and away from the case.2. Remove the 180mm fan filter as shown in the illustration.3. Unscr
SG08-LITE’s positive air pressure design is an effective configuration that will reduce dust buildup inside the case. Small air particles or lint will
La conception à pression d'air positive du SG08-LITE est une configuration efficace permettant de réduire l'accumulation de la poussière dan
1. After removing the top cover, the 180mm fan filter can slide out easily. 2. Flip the entire case upside-down, unscrew the screws holding the power
TOP COVERFAN BRACKETFAN FILTERPICTURE ITEMSCREW A M2 X 2SCREW B M3 X 4 Secure 2.5" SSD/HDDSecure optical driveSecure motherboardSecure 3.5"
SST-SOB02SOB02 is a slot-loading slim DVD burner with included SATA adapter and cableSST-NT06-PRONT06-PRO offers high performance cooling with specifi
This product has a limited 1 year warranty in North America and Australia. For information on warranty periods in other regions, please contact your
NO:G11220720
Unscrew screws holding the top cover and then remove it by pulling to the rear and away from the chassis.Unscrew screws holding the fan bracket and th
Unscrew screws holding the optical drive bracket to remove it.① Unscrew screws holding the hard drive bracket to remove it.② Loosen the screw on the P
Insert the I/O shield included with your motherboard and then install the motherboard into the case.Connect ATX 24pin, EPS 8pin/ATX 4pin connectors, f
We recommend at this point to start thinking about routing the cables cleanly by fastening ATX 24pin and EPS 8pin/ATX 4pin cables on a bridge next to
We recommend to route the USB and audio front I/O cables around the front of hard drive cage, there should be sufficient bridges for fastening the cab
Excess front panel connector cables can be fastened on the bottom panel of the case.Install and secure 3.5” and 2.5” hard drives to the hard drive cag
Commenti su questo manuale